| style="background-color:white; vertical-align: text-top;" |'''2.1''' The system shall record and maintain the chain of custody for the laboratory's standards and reagents.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.1''' The system shall record and maintain the chain of custody for the laboratory's standards and reagents.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
| style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/ | | style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-2]<br />▪ [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.14] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.2''' The system shall record the current and historical storage location for the laboratory's standards and reagents.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.2''' The system shall record the current and historical storage location for the laboratory's standards and reagents.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
| style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/ | | style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-3]<br />▪ [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.14] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.3''' The system shall allow the laboratory's previously standardized standards and reagents to be assigned a new standard value.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.3''' The system shall allow the laboratory's previously standardized standards and reagents to be assigned a new standard value.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
| style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/ | | style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-4]<br />▪ [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.14] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.4''' The system shall require the recording of a standard and reagent's first opening date.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.4''' The system shall require the recording of a standard and reagent's first opening date.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
| style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/ | | style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-5]<br />▪ [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.14] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.5''' The system shall allow only active standards and reagents to be shown as available for use.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.5''' The system shall allow only active standards and reagents to be shown as available for use.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
| style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/ | | style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-6]<br />▪ [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 4.11.14] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.6''' The system shall allow standards and reagents to be flagged as no longer available for use by authorized personnel.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.6''' The system shall allow standards and reagents to be flagged as no longer available for use by authorized personnel.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
| style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/ | | style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-7] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.7''' The system shall allow logically associated samples to be grouped together based on associated metadata such as sample type, lot or batch ID, field number, test method, assigned user, and status.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.7''' The system shall allow logically associated samples to be grouped together based on associated metadata such as sample type, lot or batch ID, field number, test method, assigned user, and status.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
| style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/ | | style="padding-left:5px; padding-top:5px; padding-bottom:5px;" |▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-8]<br />▪ [https://www.epa.gov/sites/production/files/documents/erln_lab_requirements.pdf EPA ERLN Laboratory Requirements 3.2]<br />▪ [https://www.iso.org/standard/66912.html ISO/IEC 17025:2017 7.4.2] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.8''' The system should allow for the accurate identification of a physical sample in the system via barcode or RFID technology.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.8''' The system should allow for the accurate identification of a physical sample in the system via barcode or RFID technology.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | ||
|- | |- | ||
Line 43: | Line 43: | ||
▪ [https://www.law.cornell.edu/cfr/text/42/73.17 42 CFR Part 73.17]<br /> | ▪ [https://www.law.cornell.edu/cfr/text/42/73.17 42 CFR Part 73.17]<br /> | ||
▪ [https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.2.1]<br /> | ▪ [https://www.astm.org/Standards/E1492.htm ASTM E1492-11 4.2.1]<br /> | ||
▪ [https://www.astm.org/ | ▪ [https://www.astm.org/e1578-18.html ASTM E1578-18 C-2-9]<br /> | ||
▪ [https://elss.cap.org/elss/ShowProperty?nodePath=/UCMCON/Contribution%20Folders/DctmContent/education/OnlineCourseContent/2017/LAP-TLTM/misc/lam.pdf CAP Laboratory Accreditation Manual] | ▪ [https://elss.cap.org/elss/ShowProperty?nodePath=/UCMCON/Contribution%20Folders/DctmContent/education/OnlineCourseContent/2017/LAP-TLTM/misc/lam.pdf CAP Laboratory Accreditation Manual] | ||
| style="background-color:white; vertical-align: text-top;" |'''2.9''' The system should provide a means to manually or automatically track sample inventory amounts and status, including sample weight reconciliation, while limiting data entry errors.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> | | style="background-color:white; vertical-align: text-top;" |'''2.9''' The system should provide a means to manually or automatically track sample inventory amounts and status, including sample weight reconciliation, while limiting data entry errors.<br /> <br /><hr style="width:95%; margin: auto;"><br /> <br /> |