| style="background-color:white;" |''' | | style="background-color:white;" |'''21.1''' The system should provide a means for integrating artificial intelligence (AI) into laboratory workflow as a smart agent or assistant. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-2] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-2] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.2''' The system should support ontology-based machine learning for assisting with the analysis of laboratory informatics datasets. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-3] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-3] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.3''' The system should support voice data capture and retrieval as smart laboratory assistance functions. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-4] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-4] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.4''' The system should be able to reschedule samples, change test assignments, and perform other laboratory activities based on voice command input. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-5]<br />[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, MA-6(2)] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-5]<br />[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, MA-6(2)] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.5''' The system should support predictive maintenance routines for laboratory instruments and equipment. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-6] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-6] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.6''' The system should judiciously allow various system parameters to be optimized and ideal models set within the system by AI. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-7] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-7] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.7''' The system should allow AI to algorithmically infer from past learning how to customize without explicit instruction system parameters such as aggregation, transformation, and reporting of data. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-8]<br />[https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.3]<br />[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, SI-4(5) and SI-4(7)] | | style="padding:5px; width:500px;" |[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-8]<br />[https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.3]<br />[https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf NIST 800-53, Rev. 4, SI-4(5) and SI-4(7)] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.8''' The system should monitor laboratory operation parameters (such as capacity utilization and data integrity risks) and send notifications when necessary with recommendations for immediate and corrective action. The system should also maintain a log of all such monitored operational parameters and their status changes. | ||
|- | |- | ||
| style="padding:5px; width:500px;" | | | style="padding:5px; width:500px;" | | ||
Line 61: | Line 61: | ||
[https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 9.5]<br /> | [https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 9.5]<br /> | ||
[https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 12.8 and 12.18] | [https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 12.8 and 12.18] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.9''' The system should allow for other types of facility monitoring (such as alarm, light, lock, and door statuses) and send notifications when necessary with recommendations for immediate and corrective action. The system should also maintain a log of all such monitored systems and their status changes. | ||
|- | |- | ||
| style="padding:5px; width:500px;" |[https://www.law.cornell.edu/cfr/text/42/493.1252 42 CFR Part 493.1252]<br />[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-10]<br />[https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.3] | | style="padding:5px; width:500px;" |[https://www.law.cornell.edu/cfr/text/42/493.1252 42 CFR Part 493.1252]<br />[https://www.astm.org/Standards/E1578.htm ASTM E1578-18 E-16-10]<br />[https://www.iso.org/standard/56115.html ISO 15189:2012 5.10.3] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.10''' The system should monitor instrument health (such as critical parameters and maintenance timing) and send notifications when necessary with recommendations for immediate and corrective action. The system should also maintain a log of all such monitored instrument activities and status changes. | ||
|- | |- | ||
| style="padding:5px; width:500px;" | | | style="padding:5px; width:500px;" | | ||
Line 87: | Line 87: | ||
[https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.2]<br /> | [https://www.ams.usda.gov/datasets/pdp/pdp-standard-operating-procedures USDA Sample Processing and Analysis Procedures for PDP 5.2]<br /> | ||
[https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 12.8 and 12.16] | [https://extranet.who.int/prequal/content/who-technical-report-series WHO Technical Report Series, #986, Annex 2, 12.8 and 12.16] | ||
| style="background-color:white;" |''' | | style="background-color:white;" |'''21.11''' The system should allow for environmental control and monitoring of equipment (such as incubators and freezers) and send notifications when necessary with recommendations for immediate and corrective action. The system should also maintain a log of all such monitored equipment and their associated status changes. | ||
|- | |- | ||
|} | |} | ||
|} | |} |