Difference between revisions of "File:Fig4 Capetti AdvSampPrep2022 2.jpg"
Shawndouglas (talk | contribs) |
Shawndouglas (talk | contribs) (Added summary) |
||
Line 1: | Line 1: | ||
==Summary== | |||
{{Information | |||
|Description='''Fig. 4''' GC-MS profiles of CBD standard solution obtained with MEGA-5 narrow-bore column under the following conditions: '''A''' injection of 1 µL of CBD standard solution 1 mg mL<sup>−1</sup>; '''B''' 10 µL of CBD standard solution 1 mg mL<sup>−1</sup> recovered by Vac-HSSPME after 5 minutes at 150°C; '''C''' 10 µL of CBD standard solution 1 mg mL<sup>−1</sup> recovered by HSSPME after 5 minutes at 150°C; '''D''' 10 µL of CBD standard solution 1 mg mL<sup>−1</sup> recovered after 5 minutes by Vac-HSSPME at 90°C; '''E''' 10 µL of CBD standard solution 1 mg mL<sup>−1</sup> recovered by HSSPME after 5 minutes at 90°C. GC-MS Analysis conditions: see experimental section. Legend: (1) Cannabidiol, (2) Cannabichromene, (3) Cannabinoid 1 (supposed Δ<sup>8</sup>-tetrahydrocannabinol), (4) Cannabinoid 2 (supposed Δ<sup>9</sup>-tetrahydrocannabinol). | |||
|Source={{cite journal |title=A sustainable approach for the reliable and simultaneous determination of terpenoids and cannabinoids in hemp inflorescences by vacuum-assisted headspace solid-phase microextraction |journal=Advances in Sample Preparation |author=Capetti, F.; Rubiolo, P.; Mastellone, G.; Marengo, A.; Sgorbini, B.; Cagliero, C. |volume=2 |at=100014 |year=2022 |doi=10.1016/j.sampre.2022.100014}} | |||
|Author=Capetti, F.; Rubiolo, P.; Mastellone, G.; Marengo, A.; Sgorbini, B.; Cagliero, C. | |||
|Date=2022 | |||
|Permission=[https://creativecommons.org/licenses/by-nc-nd/4.0/ Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International] | |||
}} | |||
== Licensing == | == Licensing == | ||
{{cc-by-nc-nd-4.0}} | {{cc-by-nc-nd-4.0}} |
Latest revision as of 17:58, 5 November 2022
Summary
Description |
Fig. 4 GC-MS profiles of CBD standard solution obtained with MEGA-5 narrow-bore column under the following conditions: A injection of 1 µL of CBD standard solution 1 mg mL−1; B 10 µL of CBD standard solution 1 mg mL−1 recovered by Vac-HSSPME after 5 minutes at 150°C; C 10 µL of CBD standard solution 1 mg mL−1 recovered by HSSPME after 5 minutes at 150°C; D 10 µL of CBD standard solution 1 mg mL−1 recovered after 5 minutes by Vac-HSSPME at 90°C; E 10 µL of CBD standard solution 1 mg mL−1 recovered by HSSPME after 5 minutes at 90°C. GC-MS Analysis conditions: see experimental section. Legend: (1) Cannabidiol, (2) Cannabichromene, (3) Cannabinoid 1 (supposed Δ8-tetrahydrocannabinol), (4) Cannabinoid 2 (supposed Δ9-tetrahydrocannabinol). |
---|---|
Source |
Capetti, F.; Rubiolo, P.; Mastellone, G.; Marengo, A.; Sgorbini, B.; Cagliero, C. (2022). "A sustainable approach for the reliable and simultaneous determination of terpenoids and cannabinoids in hemp inflorescences by vacuum-assisted headspace solid-phase microextraction". Advances in Sample Preparation 2: 100014. doi:10.1016/j.sampre.2022.100014. |
Date |
2022 |
Author |
Capetti, F.; Rubiolo, P.; Mastellone, G.; Marengo, A.; Sgorbini, B.; Cagliero, C. |
Permission (Reusing this file) |
Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International |
Other versions |
Licensing
|
This work is licensed under the Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
File history
Click on a date/time to view the file as it appeared at that time.
Date/Time | Thumbnail | Dimensions | User | Comment | |
---|---|---|---|---|---|
current | 17:52, 5 November 2022 | 753 × 475 (55 KB) | Shawndouglas (talk | contribs) |
You cannot overwrite this file.